Pressure Values
Ø 25 mm – Ø 110 mm : PN 16
2” – 2 ½” : PN 10
Ø 125 mm – Ø 225 mm : PN 10
3” – 4” : PN 6
Installation Areas
Urban Potable Water Networks – Landscaping Systems
Agricultural Irrigation – Greenhouses
Code | Size | Packing Qantity | Box Qantity |
---|---|---|---|
100160201 | 25 x ½” | 25 | 300 |
100160301 | 32 x ½” | 25 | 250 |
100160302 | 32 x ¾” | 25 | 250 |
100160401 | 40 x ½” | 25 | 200 |
100160402 | 40 x ¾” | 25 | 175 |
100160501 | 50 x ½” | 10 | 160 |
100160502 | 50 x ¾” | 10 | 150 |
100160503 | 50 x 1″ | 10 | 130 |
100160601 | 63 x ½” | 10 | 110 |
100160602 | 63 x ¾” | 10 | 110 |
100160603 | 63 x 1″ | 10 | 100 |
100160604 | 63 x 1¼” | 10 | 80 |
100160605 | 63 x 1½” | 10 | 80 |
100160701 | 75 x ½” | 5 | 90 |
100160702 | 75 x ¾” | 5 | 90 |
100160703 | 75 x 1″ | 5 | 80 |
100160704 | 75 x 1¼” | 5 | 55 |
100160705 | 75 x 1½” | 5 | 50 |
100160706 | 75 x 2″ | 5 | 50 |
100160801 | 90 x ½” | 5 | 75 |
100160802 | 90 x ¾” | 5 | 70 |
100160803 | 90 x 1″ | 5 | 60 |
100160804 | 90 x 1¼” | 5 | 40 |
100160805 | 90 x 1½” | 5 | 40 |
100160806 | 90 x 2″ | 5 | 40 |
100160901 | 110 x ½” | 5 | 55 |
100160902 | 110 x ¾” | 5 | 55 |
100160903 | 110 x 1″ | 5 | 50 |
100160904 | 110 x 1¼” | 5 | 35 |
100160905 | 110 x 1½” | 5 | 35 |
100160906 | 110 x 2″ | 5 | 30 |
100161001 | 125 x ½” | 2 | 44 |
100161002 | 125 x ¾” | 2 | 44 |
100161003 | 125 x 1″ | 2 | 40 |
100161004 | 125 x 1¼” | 2 | 40 |
100161005 | 125 x 1½” | 2 | 40 |
100161006 | 125 x 2″ | 2 | 40 |
100161101 | 140 x ½” | 2 | 36 |
100161102 | 140 x ¾” | 2 | 36 |
100161103 | 140 x 1″ | 2 | 36 |
100161104 | 140 x 1¼” | 2 | 36 |
100161105 | 140 x 1½” | 2 | 36 |
100161106 | 140 x 2″ | 2 | 28 |
100161201 | 160 x ½” | 2 | 26 |
100161202 | 160 x ¾” | 2 | 26 |
100161203 | 160 x 1″ | 2 | 26 |
100161204 | 160 x 1¼” | 2 | 24 |
100161205 | 160 x 1½” | 2 | 24 |
100161206 | 160 x 2″ | 2 | 22 |
100161207 | 160 x 2½” | 2 | 16 |
100161208 | 160 x 3″ | 2 | 12 |
100161209 | 160 x 4″ | 2 | 12 |
100161302 | 180 x ¾” | 2 | 10 |
100161303 | 180 x 1″ | 2 | 10 |
100161304 | 180 x 1¼” | 2 | 10 |
100161305 | 180 x 1½” | 2 | 10 |
100161306 | 180 x 2″ | 2 | 10 |
100161307 | 180 x 2½” | 2 | 10 |
100161308 | 180 x 3″ | 2 | 10 |
100161309 | 180 x 4″ | 2 | 8 |
100161402 | 200 x ¾” | 2 | 10 |
100161403 | 200 x 1″ | 2 | 10 |
100161404 | 200 x 1¼” | 2 | 10 |
100161405 | 200 x 1½” | 2 | 10 |
100161406 | 200 x 2″ | 2 | 8 |
100161407 | 200 x 2½” | 2 | 8 |
100161408 | 200 x 3″ | 2 | 8 |
100161409 | 200 x 4″ | 2 | 8 |
100161503 | 225 x 1″ | 2 | 8 |
100161504 | 225 x 1¼” | 2 | 8 |
100161505 | 225 x 1½” | 2 | 8 |
100161506 | 225 x 2″ | 2 | 8 |
100161507 | 225 x 2½” | 2 | 8 |
100161508 | 225 x 3″ | 2 | 8 |
100161509 | 225 x 4″ | 2 | 8 |
Clamp saddles should be kept away from hard and sharp objects during the storage and installation. If the installation is laid under the ground, it should be covered with sand to protect it from hard and sharp objects. Any damaged adaptor should not be used absolutely.
The o-ring should be placed in its socket properly in order not to be unsettled during the installation.
Male adaptors to be used with Clamp Saddles, should be wrapped up with the teflon band with the tightening direction and should be wrapped enough to prevent leakage.
Drilling the pipe after the installation of Clamp Saddles can cause the damage of the threads. Thus, drilling must be carried out in a way that it does not touch the threads with a suitable drill bit.
If the dimension of the installed pipes is bigger than the standard values upper and lower parts will not contact each other. Under these circumstances, there is no need to tighten the bolts till the upper and lower body parts contact or hammer the slides to the end point.
Bolts and nuts must be tightened mutually balanced during installation of the Clamp Saddles.
During installation, the system should be checked visually in order to determine the damaged clamp saddles.
After the installation, the system should be checked with water in testing pressure to determine the water leak.
● Pipe sizes do not comply with international standards,
● Other metal or plastic materials used do not comply with international standards,
● Not to use the teflon band sufficiently and suitably,
● Incorrect installation of the Clamp Saddles during installation,
● Damage of the threads of the Clamp Saddles during pipe drilling with the drill,
● Damage or displacing of the oring during the installation,
can cause leaking in your installation.
It has been produced from high quality polypropylene raw material and it has resistance to impact.
It is designed to prevent leakage caused by the size differences of the pipes.
O-rings are made of rubber and provide leakproofness under high pressure.
Thanks to the corrosion resistant metal ring used in our products, it can be used safely in systems not exceeding 50 ⁰C.
It does not contain any harmful compounds which can change the taste or the smell of the water.
It is suitable to be used for drinking water.
Reinforcing ring, bolt, nut and washers are varied as stainless steel and galvanized.
Because the nuts are inserted in their housing on the lower part, it provides quick and easy installation.
Thread sizes are compatible with ISO 7-1 Standard.
It is compatible with ISO 13460-1 Standard.