Double Clamp Saddle With Galvanized Bolt & Reinforcing Ring

Pressure Values
Ø 25 mm – Ø 110 mm : PN 16
2” – 2 ½” : PN 10
Ø 125 mm – Ø 225 mm : PN 10
3” – 4” : PN 6
Installation Areas
Urban Potable Water Networks – Landscaping Systems
Agricultural Irrigation – Greenhouses

Product Description

  • Double Clamp Saddle With Galvanized Bolt & Reinforcing Ring
  • Installation Instructions
  • Specification
  • Assembly Methods
  • Tests

Code Size Packing Qantity Box Qantity
100140201 25 x ½” x ½” 25 250
100140301 32 x ½” x ½” 25 200
100140302 32 x ¾” x ¾” 25 200
100140401 40 x ½” x ½” 25 150
100140402 40 x ¾” x ¾” 25 150
100140501 50 x ½” x ½” 10 140
100140502 50 x ¾” x ¾” 10 120
100140503 50 x 1″ x 1″ 10 120
100140601 63 x ½” x ½” 10 90
100140602 63 x ¾” x ¾” 10 90
100140603 63 x 1″ x 1″ 10 80
100140604 63 x 1¼” x 1¼” 10 50
100140605 63 x 1½” x 1½” 10 50
100140701 75 x ½” x ½” 5 80
100140702 75 x ¾” x ¾” 5 80
100140703 75 x 1″ x 1″ 5 70
100140704 75 x 1¼” x 1¼” 5 40
100140705 75 x 1½” x 1½” 5 40
100140706 75 x 2″ x 2″ 5 40
100140801 90 x ½” x ½” 5 60
100140802 90 x ¾” x ¾” 5 60
100140803 90 x 1″ x 1″ 5 50
100140804 90 x 1¼” x 1¼” 5 35
100140805 90 x 1½” x 1½” 5 35
100140806 90 x 2″ x 2″ 5 30
100140901 110 x ½” x ½” 5 50
100140902 110 x ¾” x ¾” 5 50
100140903 110 x 1″ x 1″ 5 40
100140904 110 x 1¼” x 1¼” 5 30
100140905 110 x 1½” x 1½” 5 30
100140906 110 x 2″ x 2″ 5 30
100141001 125 x ½” x ½” 2 50
100141002 125 x ¾” x ¾” 2 48
100141003 125 x 1″ x 1″ 2 42
100141004 125 x 1¼” x 1¼” 2 42
100141005 125 x 1½” x 1½” 2 36
100141006 125 x 2″ x 2″ 2 34
100141101 140 x ½” x ½” 2 36
100141102 140 x ¾” x ¾” 2 34
100141103 140 x 1″ x 1″ 2 28
100141104 140 x 1¼” x 1¼” 2 26
100141105 140 x 1½” x 1½” 2 22
100141106 140 x 2″ x 2″ 2 22
100141201 160 x ½” x ½” 2 26
100141202 160 x ¾” x ¾” 2 26
100141203 160 x 1″ x 1″ 2 24
100141204 160 x 1¼” x 1¼” 2 22
100141205 160 x 1½” x 1½” 2 20
100141206 160 x 2″ x 2″ 2 20
100141207 160 x 2½” x 2½” 2 12
100141208 160 x 3″ x 3″ 2 12
100141209 160 x 4″ x 4″ 2 10
100141302 180 x ¾” x ¾” 2 10
100141303 180 x 1″ x 1″ 2 10
100141304 180 x 1¼” x 1¼” 2 10
100141305 180 x 1½” x 1½” 2 10
100141306 180 x 2″ x 2″ 2 10
100141307 180 x 2½” x 2½” 2 8
100141308 180 x 3″ x 3″ 2 8
100141309 180 x 4″ x 4″ 2 6
100141402 200 x ¾” x ¾” 2 10
100141403 200 x 1″ x 1″ 2 10
100141404 200 x 1¼” x 1¼” 2 10
100141405 200 x 1½” x 1½” 2 8
100141406 200 x 2″ x 2″ 2 8
100141407 200 x 2½” x 2½” 2 8
100141408 200 x 3″ x 3″ 2 8
100141409 200 x 4″ x 4″ 2 6
100141503 225 x 1″ x 1″ 2 8
100141504 225 x 1¼” x 1¼” 2 8
100141505 225 x 1½” x 1½” 2 8
100141506 225 x 2″ x 2″ 2 8
100141507 225 x 2½” x 2½” 2 8
100141508 225 x 3″ x 3″ 2 8
100141509 225 x 4″ x 4″ 2 4

Clamp saddles should be kept away from hard and sharp objects during the storage and installation. If the installation is laid under the ground, it should be covered with sand to protect it from hard and sharp objects. Any damaged adaptor should not be used absolutely.


The o-ring should be placed in its socket properly in order not to be unsettled during the installation.


Male adaptors to be used with Clamp Saddles, should be wrapped up with the teflon band with the tightening direction and should be wrapped enough to prevent leakage.


Drilling the pipe after the installation of Clamp Saddles can cause the damage of the threads. Thus, drilling must be carried out in a way that it does not touch the threads with a suitable drill bit.


If the dimension of the installed pipes is bigger than the standard values upper and lower parts will not contact each other. Under these circumstances, there is no need to tighten the bolts till the upper and lower body parts contact or hammer the slides to the end point.


Bolts and nuts must be tightened mutually balanced during installation of the Clamp Saddles.

Final Check of the Installation

VISUAL CHECK

During installation, the system should be checked visually in order to determine the damaged clamp saddles.

LEAKPROOFNESS CHECK

After the installation, the system should be checked with water in testing pressure to determine the water leak.

CONDITIONS THAT MAY CAUSE LEAKAGE

● Pipe sizes do not comply with international standards,

● Other metal or plastic materials used do not comply with international standards,

● Not to use the teflon band sufficiently and suitably,

● Incorrect installation of the Clamp Saddles during installation,

● Damage of the threads of the Clamp Saddles during pipe drilling with the drill,

● Damage or displacing of the oring during the installation,

can cause leaking in your installation.

It has been produced from high quality polypropylene raw material and it has resistance to impact.


It is designed to prevent leakage caused by the size differences of the pipes.


O-rings are made of rubber and provide leakproofness under high pressure.


Thanks to the corrosion resistant metal ring used in our products, it can be used safely in systems not exceeding 50 ⁰C.


It does not contain any harmful compounds which can change the taste or the smell of the water.


It is suitable to be used for drinking water.


Reinforcing ring, bolt, nut and washers are varied as stainless steel and galvanized.


Because the nuts are inserted in their housing on the lower part, it provides quick and easy installation.


 Thread sizes are compatible with ISO 7-1 Standard.


 It is compatible with ISO 13460-1 Standard.

Assembly Methods

 


Poelsan

Contact Information

Working Hours
Monday to Friday 08.00 – 18.00
+90 (538) 519 31 19

+90 (362) 266 75 24

+90 (362) 266 77 51

www.poelsan.com

poelsan@poelsan.com

Global Brand In The Sector

We have 550 points in 75 countries…





Your Ideas Are Important To Us

Customer Satisfaction Survey





Social Media

Follow Our Activities

Fairs, Products and many of them are in our Social Media Accounts.