Female Adaptor
(Galvanized Reinforcement Ring)

Pressure Values
Ø 20 mm – Ø 10 mm : PN 6
Installation Areas
Landscaping Systems
Agricultural Irrigation – Greenhouses

Product Description

  • Female Adaptor (Galvanized Reinforcement Ring)
  • Installation Instructions
  • Specification
  • Assembly Methods
  • Tests

Code Size Packing Qantity Box Qantity
YS7211 20 x ½”
YS7212 20 x ¾”
YS7221 25 x ½”
YS7222 25 x ¾”
YS7223 25 x 1″
YS7232 32 x ¾”
YS7233 32 x 1″
YS7234 32 x 1¼”
YS7243 40 x 1″
YS7244 40 x 1¼”
YS7245 40 x 1½”
YS7254 50 x 1¼”
YS7255 50 x 1½”
YS7256 50 x 2″
YS7265 63 x 1½”
YS7266 63 x 2″
YS7267 63 x 2½”
YS7276 75 x 2″
YS7277 75 x 2½”
YS7278 75 x 3″
YS7286 90 x 2″
YS7287 90 x 2½”
YS7288 90 x 3″
YS7289 90 x 4″
YS7298 110 x 3″
YS7299 110 x 4″

 Poelsan compression fittings should be kept away from hard or sharp objects during storage or installation phases. If the installation will be under the ground, it should be covered with sand in order to keep away from contact with hard and sharp objects. Damaged fittings shouldn’t be used strictly.


To be able to get the best efficiency from Poelsan compression fittings, tee and elbow pieces should be joined with 90°, other fittings should be joined with 180° to the system. The installation with different angles will make extra tensile on the fittings and will decrease the lifetime of the system.


Teflon band should be used with the threaded pieces. The band should be used enough to prevent water leakage and wrapped on the threaded part in the twisting direction.


Over twisting of the nut will cause extra tension on the adaptor. A nut, which is exposed to such an extra tension cannot provide the guaranteed pressure value. Therefore the user should remember that the material is plastic and the nut should be twisted with a force only enough to prevent leakage.


Final Check of the Installation

VISUAL CHECK

During installation, the system should be checked visually in order to determine the damaged adaptors.

LEAKPROOFNESS CHECK

After the installation, the system should be checked with water in testing pressure to determine the water leak.

CONDITIONS THAT MAY CAUSE LEAKAGE

The measurements of the threads of Poelsan compression fittings are produced according to the standarts.

● Unfitness of the measurements of the threads of other metal or plastic metarial,

● Unefficient use of the teflon band,

● Spoiling of the threads because of the improrer installation or over twisting of the nut,

● Not chamfering the pipe during assembly causes the oring to be damaged, or dislocated,

● The ovality of pipes is more than the tolerance values,

● Wrong installation, inefficient twisting or cracking the nut by over twisting,

● Twisting the nut and installing the adaptor without joining the locking ring and the o-ring holder,

may cause leakage in the system.

It has been produced from high quality polypropylene raw material and it has resistance to impact.


Thanks to the conical tightening feature, it prevents the problems that may occur because of the size differences or ovality in pipes.


They prevent alga and bacteria forming due to UV proof (ultraviolet beam) structure.


O-rings are made of rubber and provide leakproofness under high pressure.


It has a homogeneous and non-porous inner surface.


It does not contain any harmful compounds which can change the taste or the smell of the water.


Female threaded products provide high leakproofness in changeable temperature values thanks to corrosion resistant reinforcing ring.


Thread sizes are compatible with ISO 7-1 Standard.


It is compatible with ISO 17885 Standard.


Poelsan

Contact Information

Working Hours
Monday to Friday 08.00 – 18.00
+90 (538) 519 31 19

+90 (362) 266 75 24

+90 (362) 266 77 51

www.poelsan.com

poelsan@poelsan.com

Global Brand In The Sector

We have 550 points in 75 countries…





Your Ideas Are Important To Us

Customer Satisfaction Survey





Social Media

Follow Our Activities

Fairs, Products and many of them are in our Social Media Accounts.